Description

The Cyrix Battery Combiner is a microprocessor-controlled heavy duty relay that automatically connects batteries in parallel when one of them has reached a pre-set voltage (indicating that the battery is being charged) and disconnects when the voltage decreases below float level (indicating that one or more batteries are being discharged). Cyrix Battery Combiners are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not need to be increased.

Intelligent battery monitoring to prevent unwanted switching
Some battery combiners (also called voltage controlled relay, or split charge relay) will disconnect a battery in case of a short but high amperage load. A battery combiner also may fail to connect a large but discharged battery bank because the DC voltage immediately drops below the disengage value once the batteries are connected. The software of the Cyrix-ct 12/24 does more than simply connect and disconnect based on battery voltage and with a
fixed time delay. The Cyrix-ct 12/24 looks at the general trend (voltage increasing or decreasing) and reverses a previous action only if the trend has reversed during a certain period of time. The time delay depends on the voltage deviation from the trend. (for Battery Combiners with multiple engage/disengage profiles, please see the Cyrix-i 400)

Long bolts to allow connection of more than one power cable
Cyrix 12/24-120: 13 mm (M6) Cyrix 12/24-230: 16 mm (M8)
Protection against overheating (due to a long duration overload e.g.)
The Cyrix will disengage in case of excessive contact temperature, and reengage again after it has cooled down.

LED status indication (Cyrix 12/24 230 only)
LED on: engaged LED 10 s flash: disengaged
LED 2 s flash: connecting LED 2 s blink: disconnecting
LED 0,25 s blink: alarm (over-temperature; voltage > 16 V; both batteries < 10 V; one battery < 2 V)
(multiply by two for 24 V)

12/24 V auto-ranging
The Cyrix-ct 12/24 automatically detects system voltage.

No voltage loss
Cyrix battery combiners are an excellent replacement for diode isolators. The main feature is that there is virtual no
voltage loss so that the output voltage of alternators or battery chargers does not need to be increased.

Prioritizing the starter battery
In a typical setup, the alternator is directly connected to the starter battery. The accessory battery, and possibly also a
bow thruster and other batteries are each connected to the starter battery with Cyrix battery combiners. When a Cyrix senses that the starter battery has reached the connect voltage it will engage, to allow for parallel charging of the other batteries.

Bidirectional voltage sensing and power supply from both batteries
The Cyrix senses the voltage of both connected batteries. It will therefore also engage if for example the accessory
battery is being charged by a battery charger.
The Cyrix-ct 12/24 has a dual power supply. It will therefore also close if the voltage on one battery is too low to operate the Cyrix. In order to prevent unexpected operation during installation or when one battery has been disconnected, the Cyrix-ct 12/24 will not close if the voltage on one of the two battery connections is lower than 2 V (12 V battery) or 4 V (24 V battery).

Parallel connection in case of emergency (Start Assist)
The Cyrix can also be engaged with a push button (Cyrix remains engaged during 30 seconds) or a switch to connect
batteries in parallel manually.
This is especially useful in case of an emergency when the starter battery is discharged or damaged.

Important Notice: Livestainable relies on the relevant suppliers/manufacturers and/or third-party sellers to provide adequate information displayed on the products we promote on Livestainable.co.za. Therefore, in some cases Errors and Omissions could be expected.

Noticed incorrect information or an issue with this page? Let us know

Additional information

Weight 2 kg !
Shipping Dimensions L 4.6 × W 4.6 × H 8 (cm) !
Brand

Warranty

Brand

Victron Energy

SKU CYR010120412
CATEGORY
TAGS , , ,

Downloads

Datasheet-Cyrix-Li-ion-120-A

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)