Description
Geyserwise TSE1 – Geyser Timer and Temperature Controller with Display
Dual-Purpose Timer for Thermosyphon Solar Systems & Electric Geysers
Designed for flexibility and efficiency, this device acts as a vital component for managing both Thermosyphon Solar Systems and traditional Electric Geysers. It offers streamlined control over your water heating process, ensuring that you achieve optimal temperature regulation and energy savings with ease.
Enhanced Features for Maximum Efficiency:
- Dual Functionality: Serves as an effective timer for both thermosyphon solar systems and standard electric geysers, facilitating easy integration and versatile use.
- Comprehensive Display: The clear, intuitive display provides immediate access to water temperature, time, day, heating mode, and alerts for any malfunction conditions, keeping you fully informed.
- Flexible Heating Control: Choose between automatic or manual heating, with a simple temperature adjustment feature catering to your specific needs, ranging from 30°C to 75°C, with a convenient factory default set at 55°C.
- Personalized Settings: Offers four distinct temperature settings alongside a daily programmable timer with four timer options, allowing for tailored heating schedules that match your daily routine.
- Safety and Alerts: Advanced warning system notifies you of any error conditions with codes from E2 to E5 and E7, while an electronic thermostat with a mechanical thermal cut-out at 90°C ensures safe operation, especially in solar systems that might experience higher temperatures.
Technical Specifications for Reliable Performance:
- Voltage and Power: Operates on 230VAC / 50HZ, with a main relay contact rating of 30AMP (Max 4KW) and an operating voltage range of 220V – 250V AC.
- Temperature Management: Displays temperatures ranging from 0°C to 99°C, with special indicators for extreme temperatures. It includes a high temperature warning above 84°C and precise temperature setting ranges from 30°C to 75°C for electrical heating.
- Advanced Detection Features: Equipped with heat failure detection for rate increases less than 4°C per hour, mechanical thermal cut-out at 90°C for additional safety, and dry heat detection to prevent operation on an empty cylinder.
- Accuracy and Monitoring: Offers a temperature tolerance of ± 2%, a temperature differential setting of 1°C, and a switching differential of 6°C. It also includes temperature probe failure detection for the tank and a wide temperature probe range for the geyser (-30 to +130°C).
This dual-purpose timer is an essential tool for anyone looking to streamline their water heating system. It combines functionality, safety, and user-friendly features to provide a comprehensive solution for both thermosyphon solar systems and electric geysers, ensuring that you maintain perfect control over your water heating needs.
What’s Included ?
- Geyserwise TSE1 Display
- Geyserwise TSE Power Supply
- Geyserwise Thermal Cut Out
- Geyserwise TSE Installation Manual
Watch: How to set Geyserwise timers
Important Notice: Livestainable relies on the relevant suppliers/manufacturers and/or third-party sellers to provide adequate information displayed on the products we promote on Livestainable.co.za. Therefore, in some cases Errors and Omissions could be expected.
Noticed incorrect information or an issue with this page? Let us know